Sterile moduleCycle · BI/CI · filter test

Sterilisation cycle management software — a failed cycle cannot be released.

Swat iQua Suite records every sterilisation cycle with its equipment, load and parameters, captures biological and chemical indicator results, and lets QA release only cycles that passed — never their own. Sterilising-filter integrity tests are verified the same way, and a failure blocks the batch.

  • Moist heat, dry heat, depyrogenation, gas, radiation, filtration
  • BI/CI results on every cycle
  • QA release: operator can’t release own cycle
  • Filter test failure raises a deviation and release blocker
Sterile production area with operators in cleanroom garments

Autoclave cycle records

Every cycle, from plan to QA decision.

  1. Planned

    Plan the cycle

    Cycle type, equipment, load number and related batch.

  2. In Progress

    Run

    The cycle runs and its parameter summary is recorded.

  3. Completed

    Record results

    Biological and chemical indicator results are entered against the cycle.

  4. Released / Rejected

    QA decision

    A segregated, e-signed QA release. A cycle with a failed BI or CI cannot be released.

What is recorded

Sterilisation and filtration in one controlled record set.

  • Six cycle types

    Moist heat, dry heat, depyrogenation, gas, radiation and filtration cycles, each with equipment, load number and parameter summary.

  • BI/CI results

    Biological and chemical indicator results recorded against each cycle. A failed indicator blocks release.

  • Segregated QA release

    The operator who ran a cycle cannot release it. Release is e-signed.

  • Filter integrity testing records

    Bubble point, diffusive flow and water intrusion tests, pre-use and post-use.

  • Verified filter tests

    Each filter integrity test is verified by a second person with an e-signature.

  • Sterile impact

    A failure raises a deviation and a release blocker on the related batch.

    Deviation management

How it works

Sterilisation evidence that reaches the release decision.

Sterilisation and sterile filtration are critical steps where a single failed cycle or filter can compromise a batch. GMP guidance, including EU GMP Annex 1, expects each cycle to be recorded with its parameters and indicator results, sterilising filters to be integrity tested, and failures to be investigated before product is released. Swat iQua Suite covers the Annex 1 controls for these records and connects them to the batch.

Cycles and indicators

Each cycle is recorded with its type, the steriliser or other equipment used, the load number, a parameter summary and, where relevant, the batch it served. Biological and chemical indicator results are entered against the cycle. QA release is a segregated duty — the operator cannot release their own cycle — and it is e-signed. The server refuses to release a cycle whose BI or CI failed, so a failed load cannot slip through on a busy shift.

Filter integrity tests

Sterilising-filter integrity tests are recorded by method — bubble point, diffusive flow or water intrusion — and as pre-use or post-use. Each test is verified by a second person with an e-signature. A failed test drives the sterile-impact process: a deviation is raised for investigation and a blocker is placed on the batch’s release dossier, so QA sees it before any release decision.

  • Sterilisation cycles appear as a live count on the operations control tower.
  • Release blockers flow into the batch release checklist automatically.
  • Deviations raised by failures follow the normal investigation and CAPA route.

FAQ

Frequently asked questions

Can’t find your answer? Talk to our team — we reply within one business day.

Which sterilisation methods are supported?

Moist heat, dry heat, depyrogenation, gas, radiation and filtration cycles, each recorded with equipment, load number, parameter summary and BI/CI results.

Can a cycle with a failed biological indicator be released?

No. The server refuses QA release of any cycle with a failed biological or chemical indicator. The cycle can be rejected instead.

Who can release a sterilisation cycle?

A QA user other than the operator who ran it. Release is e-signed.

Which filter integrity tests can be recorded?

Bubble point, diffusive flow and water intrusion tests, recorded as pre-use or post-use and verified by a second person with an e-signature.

What happens when a filter test fails?

The sterile-impact process raises a deviation and places a release blocker on the related batch, which must be resolved before release.

Ready to see Swat iQua Suite in action?

Book a free, personalised demo and see how Swat iQua Suite takes your plants, labs and quality teams from paper to inspection-ready.

Download the brochure →