Quality · eQMSChange Control

Change control software that proves the change worked.

Swat iQua Suite change control software takes every GMP change from proposal through review, approval and a documented decision to verified change actions, closure and an effectiveness review — with four different people in the chain and every step in the audit trail.

  • 4-actor segregation of duties
  • Per-site e-sign on approval
  • Verified change actions with overdue gate
  • Effectiveness review after closure

Real product footage

Watch a change decided and signed.

Change lifecycle

From proposal to an effective change.

Created → In Review → In Approval → Approved → Decision Taken. Reject closes the change; Proceed opens the change actions, then In Close → Closed and, where required, Closed – Effectiveness Pending → Closed.

  1. ProposeCreated

    Change proposed

    Department, impact category and classification recorded by the initiator.

    Created
  2. ApproveReviewer ≠ approver

    Reviewed & approved

    Two further people review and approve; approval can require an e-signature per site.

    Approved
  3. DecideProceed / Reject

    Decision & actions

    A decision-taker proceeds or rejects. Change actions are owned, verified and kept on time.

    Action pending
  4. VerifyEffectiveness

    Effectiveness review

    After closure, a reviewer other than the initiator confirms the change achieved its aim.

    Closed

Interim close is available for long-running actions; the effectiveness review waits until the change is fully closed.

Key capabilities

A GMP change control system with real separation of duties.

  • 4-actor segregation of duties

    Initiator ≠ reviewer ≠ approver ≠ decision-taker, enforced on the server. The effectiveness reviewer must not be the initiator.

  • E-signed approval

    Sites can require a password re-authentication when a change is approved.

  • Verified change actions

    Each change action has an owner and is verified. Extensions only move dates forward, and an overdue action cannot be verified without one.

  • Interim close

    Close the change with an e-signed justification while long-running actions finish.

  • Impact and classification

    Department, impact category and a four-code classification on every change, for consistent triage and reporting.

  • Controlled print & API

    Controlled print, preview and blank form, REST API access and inclusion in the daily overdue digest.

How it works

Change control on the same discipline as your deviations.

Change control in Swat iQua Suite shares the deviation lifecycle — the same review, approval and decision steps and the same four-person separation — and adds an effectiveness review after closure. QA teams learn one way of working, and inspectors see the same controls applied to planned and unplanned events.

Change actions are the corrective mechanism

Once a change is approved and the decision-taker chooses to proceed, the work is carried out as change actions. Each action has an owner and a due date and is verified by someone else. Requests for more time are logged as extensions that can only move a date forward, and the system refuses to verify an overdue action that has no approved extension.

Change control does not raise CAPAs. Its corrective mechanism is its own set of verified change actions, which keeps the change record complete in one place rather than split across registers.

Effectiveness review

After closure a change can sit in Closed – Effectiveness Pending until a reviewer confirms the change achieved what it set out to do. The reviewer must not be the person who initiated the change, and the review is blocked while the change is only interim-closed, so effectiveness is judged on a finished change.

Assessing the risk of a change

Where a change needs a structured risk assessment, QA can open an FMEA register in Quality Risk Management scoped to that change. When a change touches an SOP, the revised SOP goes through its own review, approval and make-effective steps in SOP & Document Control, and training follows from the new version.

Regulations

Designed to support controlled change under GMP.

  • US FDA cGMP

    Changes to procedures, specifications and processes reviewed and approved by the quality unit before they take effect.

    FDA cGMP
  • EU GMP Annex 11

    Changes made in a controlled manner, with an audit trail of who changed what, when and why.

    EU GMP Annex 11
  • Revised Schedule M

    A documented change control system with review, approval and follow-up of each change.

    Revised Schedule M

FAQ

Frequently asked questions

Can’t find your answer? Talk to our team — we reply within one business day.

What is change control software in pharma?

It manages proposed changes to GMP processes, documents, equipment or systems through a controlled review, approval and implementation workflow. In Swat iQua Suite this includes verified change actions and an effectiveness review after closure.

How many people are involved in approving a change?

Four: the initiator, reviewer, approver and decision-taker must all be different people. The person who reviews effectiveness must not be the initiator.

Does change control raise a CAPA?

No. Change control uses its own change actions, with verification and an overdue gate, as its corrective mechanism. CAPAs come from deviations, OOS investigations, audits and other quality events.

Can a change be closed before all actions are done?

Yes, by interim close with an e-signed justification. The remaining actions must still be completed, and the effectiveness review cannot start until the change is fully closed.

Ready to see Swat iQua Suite in action?

Book a free, personalised demo and see how Swat iQua Suite takes your plants, labs and quality teams from paper to inspection-ready.